This loop initialization may not be noticeable from ONTAP.ENC_out may be seen on loops connecting to a fabric (FMC for example) if a disk is changed or the loop initializes for any other reason. CRC and ENC_IN are pointing to a SFP and/or ASIC issue. Statistically, crc_err and enc_out errors together imply a GBIC/SFP problem.Receiving port uses the same formula to check and compare.

brocade san switch netapp array l-port to f-port

  • A mathematical formula generates counters at sending port.
  • This measured ratio is affected by many factors including: signal to noise, distortion, and jitter.
  • The ratio of how many bits received in error over the number of total bits received is the BER.
  • brocade san switch netapp array l-port to f-port

  • The BER is calculated by comparing the transmitted sequence of bits to the received bits and counting the number of errors.
  • brocade san switch netapp array l-port to f-port

    The Bit Error Rate (BER) formula is BER= Nerr/Nbits.

  • Everything hitting the wire is encoded using 8/10b encoding.
  • Reinitialization/reboots of the associated Nx-port can also cause these errors.
  • Minimum compliance with the link bit error rate specification on a link continuously receiving frames would cause approximately one error every 20 minutes.
  • Words inside of frames are encoded, if this encoding is corrupted or an error is detected, enc_in is generated.
  • 8bit/10bit encoding errors inside frame.
  • The output displays a message similar to the following:įrames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout
  • For proper analysis, the stats for the ports should be cleared ( portstatsclear or statsclear) and the switch should be run for some time to see what errors are currently accumulating, if any.
  • Errors in porterrshow are cumulative since the last time errors were cleared.





  • Brocade san switch netapp array l-port to f-port